B use a wrb that is vapor permeable on the top of the roof sips underneath the standing seam metal roof so that if somehow any moisture does get down to the roof sips it has the ability to permeate outward.
Unvented roof using sips.
This will create an air space over your panels which will allow them dry out if moisture escapes.
Beams on 5 centers.
Sip s are almost air tight and won t leak air so you don t need ventilation.
The ventilation space can be eliminated and the construction greatly simplified by using an unvented roof assembly.
Do use only continuous 2 bys i beams and insulated i beams for spline connections.
Extreme s pre insulated sips offer an option for a high performance roof framing solution that is 15 times tighter than conventional construction practices making it easier to control indoor air environment.
Unvented roof assemblies should be insulated either with air impermeable insulation rigid foam or spray polyurethane foam or with a combination of foam and air permeable insulation.
Do use sip tape or equivalent vapor retarder on roof panel joints.
3 8 plywood diaphragm seams taped.
Four options for building an unvented roof assembly.
Cold roof a cold roof is achieved by adding strapping and another layer of sheathing over the sips.
Next i ll be screwing down 5 1 2 raycore sips panels over heated space and framing boxes over the eaves covering everything with 5 8 cdx.
Do use sealant on wood to wood wood to eps and eps to eps connections.
A sure bet would be to use 6 of eps above the roof deck or a 6 sip for r25 then finish it out with 6 of better quality high density spray fiberglass sprayed onto the underside of the roof deck to acheive an even better clear assembly r value than 14 of blown fiberglass since the eps is now thermally breaking the i joists.
If you don t want to use sips or nailbase there are four basic approaches.
This is a pretty common procedure when using roof sips.
We feel a cold roof is not necessary if your roof sips are sealed properly.
Closed cell spray polyurethane foam can be used to create an unvented roof assembly that works in all climate zones.
Do install proper flashing and sealants around all rough openings and penetrations as required.
Cost aside the most straightforward route is spraying closed cell polyurethane foam on to the underside of the roof deck.
The roof is currently built as follows.
The design approach is the same for all climate zones.
Need to make a final decision on which underlayment to use under a metal roof on an unvented roof system.
A use a material that is not vapor permeable over the t g ceiling boards and under the roof sips to prevent moisture migration from inside the building to the underside of the roof sips.
With tribuilt granulated self adhering underlayment on top of the plywood.
1 1 2 t g decking.
Build for the future with extreme s structural insulated panels sips the high thermal values and strength properties of extreme s sips are highly beneficial for roof construction.